20 WATTS 2 x EL84 MONO AMP. PARTS LIST AND SPECIFICATIONS: _______________________________________________________ Rated Power Output: 20 Watts Frequency Response: 30Hz - 15kHz (+/-3dB) THD: 2% (1kHz/20W) Signal to Noise: 85dB (Input Shorted) Input Sensitivity: 500mV RESISTORS: R1,R5,R6,R7 = 1M R2,R8 = 2.2k R3,R9 = 220k R4 = 560R R6 = 150k R9 = 220k R10,R11,R14,R15 = 470k R12,R13,R18,R19 = 110R R16,R17 = 10R/0.5W R20 = 100k R21 = 22k R22 = 15k R30 = 33k TR1,TR2 = 1M trimmpot TR3 = 220R/0.25W wire wound trimpot. L1 = lamp 10V 50mA CAPACITORS: C1 = 0.047uF/100V C2,C5 = 47uF/16V C3,C4 = 0.033uF/400V C6 = 0.027uF/400V C7 = 47uF/50V C10 = 100uF/450V C11 = 47uF/450V T1 = Output Transformer - no data available D1 = 1N4148 Power Transformer: Secondary: 2 x 300VAC 125mA Filament1: 6.3VAC/1.2A Filament2: 6.3VAC/2A Tubes: V1 = ECC83 V2,V3 = EL84 V4 = EZ81 Calibration Procedure: Make sure all wiring and connections are correct. Remove tubes V2 and V3 from sockets, leave only V1 inserted. Short amplifiers input to common ground. 1. Set both trimmpots TR1 and TR2 in center position. 2. Turn on power and check voltage at TP1, adjust with TR2 to ca. -20V. Next turn off power and insert both power pentodes V2 & V3. 3. Turn on power and let the tubes warm up. Connect DVM between the control grids of the pentodes, adjust with TR1 to zero Volts. Set DVM to 1 Volt scale and reset again to zero Volts. 4. Next connect DVM to common ground and one of the pentode cathodes, adjust with TR2 to 580mV (0.58V). 5. Now connect DVM between the two pentode cathodes and adjust with TR1 to zero volts, use lower scale. 6. Finally measure voltage between common ground and cathodes of both pentodes. Should be 580 mV +/- 20mV. Repeat steps 3-5 if needed.